Characteristic parameters | conditions | MIN | TYP | MAX | UNIT |
---|---|---|---|---|---|
Input voltage | Ta=-40~85℃ | 1.7 | 2.8 | 5.5 | V |
Wake up mode current | Vs=3V, Ta=25℃ | 1.5 | 3 | mA | |
Dormant mode current | Vs=3V, Ta=25℃ | 3.5 | 7 | uA | |
Average current | Vs=3V, Ta=25℃ | 5.0 | 10 | uA | |
Wake Up Time | Vs=3V, Ta=25℃ | 40 | 80 | us | |
Cycle time | Vs=3V, Ta=25℃ | 30 | 40 | 80 | ms |
Operating point (positive) | Vs=2.2V~5.5V Ta=-40~85℃ | 20 | 55 | Guass | |
Release point (positive) | Vs=2.2V~5.5V Ta=-40~85℃ | 10 | 45 | Guass | |
Operating point (minus) | Vs=2.2V~5.5V Ta=-40~85℃ | -55 | -20 | Guass | |
Release point (minus) | Vs=2.2V~5.5V Ta=-40~85℃ | -45 | -10 | Guass | |
Work temperature | Vs=2.2V~5.5V | -40[-40] | 85[185] | ℃[℉] | |
Storage temperature | Vs=2.2V~5.5V | -40[-40] | 150[302] | ℃[℉] | |
High level | Vcc | V | |||
Low level | Vs=5V R=10k | 0.5 | V | ||
N/S trigger | Low level | ||||
Magnetic field disappeared | High level |